Home > HARDWARE > CONSTRUCTION HARDWARE > JOIST HANGERS & CONNECTORS
Choose a sub category:
JOIST HANGERS FRAMING ANGLES/ANCHORS MENDING PLATES
NAIL PLATES POST ANCHORS / CAPS FENCE BRACKETS
BRIDGING INSULATION SUPPORTS STRAPS
PLYWOOD CLIPS FOUNDATION ANCHORS BRICK/WALL TIES
MISC CONSTR HARDWARE
Sort By:
1 2 3
Ties trusses and rafters to top plates either left or right handed. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. G90 galvanizing finish. Requires 8d nails for installation in plate and rafter/truss. Meets ICC-ES ESR-1465 and FL817 codes. 18 Gauge. Designed for quick installation of purlins between rafters, joists or trusses in post and beam structures. One-piece construction assures a consistent flush fit between purlin and joist or rafter. A reinforced "double lap" seat boosts the load capacity of this heavy-duty purlin hanger. Requires (4) 10d x 1-1/2" nails for header and (4) 10d" nails for each purlin. Features a 1-9/16" top fold; pending IAPMO-ES evaluation. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed.
Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments.
Standard stock 45 degree skew hanger for common standard lumber, engineered lumber and plated truss applications. Flexible design for 40 to 50 degree skew range. Meets ICC-ES ESR-1781, FL13285, L.A. City RR25843 and Dade County, FL 11-0510.01 codes. For additional information including allowable loads and fasteners, Please See USP Structural Connectors charts in the Orgill paper catalog R7 Reference Pages. Joist size is adjustable in 2 inch increments. Replace wood blocking on roof sheathing. Tight fit for positive installation. Embossed dimples provide 1/8" gap needed to prevent panels from popping up as sheathing expands. G60 galvanizing finish. 20 Gauge - Boxed. With built-in spacer for use when support spacing exceeds the maximum length of an unsupported edge. Boxed.
You determine the size. Connect with railing brackets with 2x4 and 2x6 lumber to easily add a bench to any size or shape deck. Gain increased seating area while using only 7" of deck space. Assembled unit stands 36"H for deck railing, seat is 17"H. Quick and easy to assemble using basic tools. Includes bench bracket, hardware and instructions. LUMBER NOT INCLUDED. Structurally rated. For use with USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Structurally rated. For use with USP Lumber Connectors' products. For additional information including withdrawal load and allowable shear per nail, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed.
Enables cut-to-length convenience for job site needs. G90 galvanizing finish. 1-1/2" nail spacing. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Boxed.
Masonry accessory used to tie a brick veneer to the exterior of the house. 2 holes provide for nailing on one end; other end is bent to lie between the mortar joints. Follow local codes for spacing. 6-3/8" x 7/8". Used to secure wood posts to concrete footings and to provide moisture damage protection. 4-sided with high uplift and bearing capacity. Features a 1" stand-off plate to evaluate wood posts above concrete surfaces. Drain slots allow the anchors to shed water. Triple zinc finish for ACQ pressure treated lumber. Not recommended for fence posts or unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR25836 codes. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Secures batt-type insulation in place between joists. Chisel cut ends dig into joists for permanent holding. Easy to install in hard-to-reach crawl spaces. Pushes into place. Overall length is 1/2" less than over center joist spacing. 13 Gauge.
Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist/header installations. Does not have tabs. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505; ICBO 5736; DSA PA-076; Dade County, FL 01-0417.11; and  L.A. City RR25303 codes. 18 Gauge. System eliminates the damage to deck boards by hiding all fasteners beneath deckboards. Holds boards tight to eliminate any surface penetration. No moisture can enter deckboards or joists and cause nail penetration. No moisture can enter deckboards or joists and cause nail or screw pop-ups or deck rot. No stains or splinters form around fastener holes. Corrosion resistance. Powder coating's natural wood color blends with the understructure of balconies. For: 3/4" thick boards, composites less than 1-1/8", and any hollowcore composites. Consumer pack includes: 10 brackets, (120) 10 x 1" deck board screws, (110) 8 x 1" joist screws, and a pro bit tip.
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For securing mudsills and framing into concrete slabs or poured stemwalls. Not Recommended for block installation or securing concrete sections together between cold joints. Features prebent base flange for proper anchoring into concrete. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets  NER 530 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
G90 galvanizing finish. Meets ICC-ES ESR-1781, FL43285, Dade county, FL11-0510.01 and L.A. City RR25843 codes. For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
For light-duty post-to-beam connections. Quick and easy installation on decks, carports and other projects. Use two caps for each installation project to act as a unit. Designed to work with single, solid sawn beams, but can be used with build-up beams made of 2x lumber and shims fastened. "-TZ" following item number indicates Triple Zinc finish. "-GC" following item number indicates Gold Coat finish. Meets ICC-ES ESR-1781, FL18285 and L.A. City RR25843 codes. For additional information including allowable loads loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Easy to install for protecting plumbing and power or communication wiring from screw or nail penetration. 16 gauge, 1/16" thick. Conforms to National Electric Code. Offers anchor bolt adjustment slots.
Easy-to-install for protecting plumbing and power or communication wiring from screw or nail penetration. Conforms to National Electric Code. 16 Gauge - 1/16" Thickness. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Joins flat surfaces of 2 or more wood members. Not intended for structural use or use in truss assembly. G90 galvanizing finish. Use nails appropriate for intended use. Holes sized for 8d common or 8d x 1-1/2" nails. 20 Gauge.
Holds up rafters and joists, eliminating the need for two people. Automatically levels the crossmember with the rimjoist or ledger giving the framer a "hands free" position while installing the joist hanger or other connectors. Clamps down on target from the top or the bottom and holds lumber tight. Reusable and made of zinc plated durable steel. For all 2x wood framing or less. Decking, roofing, and flooring applications. Includes 2 joist jaws per package. Provides a raised base that elevates wood posts above concrete surfaces to avoid moisture from ground contact. Single-piece design made from composite material; will not corrode. Open center enables installation of metal rod from concrete into post. Not recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning moment loads. Requires (4) 10d HDG nails. ACQ approved. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. Ties trusses and rafters to top plates. Can use to tie wood framing members to resist uplift and lateral forces. Seismic, tested for lateral movement. Triple Zinc anchors (310.1573) requires 8d HDG nails and Gold Coat anchors (947.3265) requires N8-GC nails.  Meets ICC-ES ESR-1465 and FL817codes. For additional information including allowable loads and number of fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Prong plates with straight prongs. Joins flat surfaces of 2 or more wood members. Not Intended for structural use OR use in truss assembly; No load ratings assigned. G90 galvanizing finish. 22 Gauge. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Seamless, keeps water off post tops to protect wood from moisture damage. Corrosion-proof and paintable. Requires one 8d HDG or 10d HDG nail for installation. 3-5/8"W - For 4 x 4 Post/Column.
Connects wood framing to resist tension forces. G90 galvanizing finish. LSTA Light-duty Series require 10d nails for installation. Designed for use with 1-1/2"W framing members, including I-Joist flanges. Meets ICC-ES ESR-1781 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Reinforces 90 degree wood-to-wood connections. G90 galvanizing finish. Requires 16d nails for installation. 12 Gauge. Medium-duty straps connect beams to posts. Requires either (3) 1/2" bolts or (12) 16d nails for installation. Triple Zinc straps require HDG bolts or 16d HDG nails for installation.
Use for joist to header, rafter to plate, stud to plate or 1" foamboard installations. Achieves continuous load path in high wind and seismic resistant construction. Enables quick field adjustments for 2 and 3-way connections. Tabs enable two and three-way connections. Bend tabs only once. G90 galvanizing finish. Requires 8d x 1-1/2 nails. Meets SBCCI, BOCA - NER 505, ICBO 5736, DSA PA-076, Dade County, FL 01-417.11 and  L.A. City RR25303 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. Double shear nailing for fewer nails and faster installation. Dimples allow for 30 to 45 degree nailing through joist into header, resulting in higher loads and less nailing, and eliminate need for shorter joist nails in 2x applications. Meets ICC-ES ESR-1881, FL821, L.A. City RR25779, Dade County, FL 11-0510.01 and 07-0419.01codes. For additional information including allowable loads and fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. For securing mudsills and framing into concrete slabs. Do Not rely-on for securing concrete sections together between cold joints. Features split flange for nailing to both mudsill and stud for greater framing versatility. Use a minimum of 2 anchors per mudsill within 12" of the end of each section. Meets ICC-ES ESR-2787 codes For additional information including allowable loads and fasteners, please see USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages.
Used to strengthen framing in various applications or to support joists where stirrup style hangers cannot be installed. Requires 10d x 1-1/2 nails for installation. Meets ICBO, SBCCI, BOCA - NER 505; L.A. City RR25303, DSA PA-076; and Dade County, FL 98-0421.06 codes. For additional information including allowable loads and number of fasteners, Please See USP Lumber Connectors charts in the Orgill paper catalog R7 Reference Pages. 16 Gauge. Used to secure wood posts to concrete footings and to provide moisture damage protection. 2-sided with high uplift and bearing capacity. Features a 1" stand-off plate to elevate wood posts above concrete surfaces. Not recommended for fence posts or other unrestrained (not fixed or fastened at top) applications. Not designed to resist overturning (moment) loads. Requires 16d nails for installation. Meets ICC-ES ESR-1831, FL822 and L.A. City RR 25836 codes. Create a workbench, worktable or power tool stand. Add 2x4's plywood or particleboard to make a workbench, worktable or power tool stand in any length or width up to 8'L x 4'W. Simple assembly in less than an hour with only powered screwdriver and a saw. Only straight, 90-degree cuts required, no miter or angles. Made of structural resin.  Kit includes: 4 legs, hardware and instructions. LUMBER AND SHELF LINKS NOT INCLUDED.
   
 
1 2 3