Eaton CL230 Type CL Circuit Breaker Connecticut UBIZ230 Type UBIZ Full Circuit Breaker Connecticut UBIF Standard Thin Type NC Circuit Breaker
Eaton Circuit Breaker, Type CL, 120/240 V, 30 A, 1 Phase, 10 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 14 - 4 AWG Wire, Plug On Mounting, 1 in Spacing, For Load Centers Connecticut Circuit Breaker, Type UBIZ, Full, 120/240 V, 30 A, 1 Phase, 125A Frame, 10 kA Interrupt, 2 Poles, 14 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 4.9 in Overall Length, 1-1/2 in Overall Width, 2-3/4 in Overall Depth, ANSI Specified, UL Listed, Panelboard Mount, Used in Zinsco QC30 Series Load Centers, Hot Water Heaters, Clothes Dryers Connecticut Circuit Breaker, Standard, Thin, Type NC, Connecticut, Series: UBIF, 120/240 V, 20 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 10 AWG Wire, Lug Terminal, Plug In Mounting, 3.35 in Overall Length, 1 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers
Connecticut UBIF Standard Thin Type NC Circuit Breaker Connecticut UBIF Standard Thin Type NC Circuit Breaker Connecticut UBIF Standard Thick Type NA Circuit Breaker
Connecticut Circuit Breaker, Standard, Thin, Type NC, Connecticut, Series: UBIF, 120/240 V, 30 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 10 AWG Wire, Lug Terminal, 3.35 in Overall Length, 1 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers Connecticut Circuit Breaker, Standard, Thin, Type NC, Connecticut, Series: UBIF, 120/240 V, 40 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 8 AWG Wire, Lug Terminal, 3.35 in Overall Length, 1 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers Connecticut Circuit Breaker, Standard, Thick, Type NA, Connecticut, Series: UBIF, 120/240 V, 30 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 3.35 in Overall Length, 2 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers
Connecticut UBIF Standard Thick Type NA Circuit Breaker Connecticut UBIF Standard Thick Type NA Circuit Breaker Connecticut UBIF Thick Residential Type NA Circuit Breaker
Connecticut Circuit Breaker, Standard, Thick, Type NA, Connecticut, Series: UBIF, 120/240 V, 40 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 6 AWG Wire, Lug Terminal, Plug In Mounting, 3.35 in Overall Length, 2 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers Connecticut Circuit Breaker, Standard, Thick, Type NA, Connecticut, Series: UBIF, 120/240 V, 50 A, 1 Phase, 125A Frame, 10000 A Interrupt, 2 Poles, 14 - 6 AWG Wire, Lug Terminal, 3.35 in Overall Length, 2 in Overall Width, 2.65 in Overall Depth, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers Connecticut Circuit Breaker, Thick, Residential, Type NA, Connecticut, Series: UBIF, 120/240 V, 60 A, 1 Phase, Instantaneous Trip, 10000 A Interrupt, 2 Poles, 10 AWG Wire, Plug In Mounting, ANSI/UL 489, ETL Listed, For Use in Federal Pacific Electric Load Centers
   
 