Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - MAIN
Sort By:
1
HomeLine HOM2100CP Standard Circuit Breaker Square D QOM100VHCP Type QO Standard Circuit Breaker GE THQMH125CP Type THHQL Top Feed Circuit Breaker
HomeLine Circuit Breaker, Standard, 120/240 VAC, 100 A, 1 Phase, 100A Frame, Fixed Trip, 135 A Trip, 10 kA Interrupt, 2 Poles, 4 - 2/0 AWG Wire, Screw Terminal, Plug On Mounting, 3-1/2 in Overall Length, 2 in Overall Width, 2.98 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Main, For Overload and Short Circuit Protection Square D Circuit Breaker, Type QO, Standard, 120/240 VAC, 100 A, 1 Phase, 100A Frame, Fixed Trip, 22 kA Interrupt, 2 Poles, 4 - 2/0 AWG Wire, Box Lug Terminal, Bolt On Mounting, 5.09 in Overall Length, 5 in Overall Width, 3.47 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, For Load Center Main Breaker GE Circuit Breaker, Type THHQL, Top Feed, 120/240 VAC, 125 A, 22 kA Interrupt, 2 Poles, Box Terminal, 60 - 75 deg C, Includes: Mounting Base, THQMH000 Retainer Kit, THHQL Breaker, For Power Mark Gold Load Centers
Eaton BW2200 Circuit Breaker Eaton BJ-2200 Type BJ Circuit Breaker Square D QDL22200 Type QDL Standard Circuit Breaker
Eaton Circuit Breaker, 120/240 VAC, 200 A, 1 Phase, 10 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 2/0 AWG - 300 KCMIL Wire, Bolt On Mounting, 3 in Overall Length, 2 in Overall Width, 6-1/4 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Main Eaton Circuit Breaker, Type BJ, 120/240 VAC, 200 A, 1 Phase, 200A Frame, 22 kA Interrupt, 2 Poles, Thermal Magnetic Actuator, 2/0 AWG - 300 KCMIL Wire, Plug On, Bolt In Mounting Square D Circuit Breaker, Type QBL, Standard, 240 VAC, 200 A, 1 Phase, 250A Frame, Fixed Trip, 25 kA Interrupt, 2 Poles, 4 AWG - 300 KCMIL Wire, Lug Terminal, Plug In Mounting, 6.47 in Overall Length, 4-1/2 in Overall Width, 3.93 in Overall Depth, ANSI Specified, CSA Certified, UL Listed, Main, For Panelboards and Switchboards
Square D QO130M200PRB QO Main Breaker Load Center
Square D Main Breaker Load Center, Series: S06, QO, 120/240 VAC, 200 A, 1 Phases, 3 W, Main Circuit Breaker, Plug On, 30 Spaces, 30 Circuits, NO 4 - 250 AWG/kcmil (Al/Cu) Cable, Overhead/Underground Feed, Rainproof Cover, Copper Buss Bar, Plug-In Mounting, Thermoplastic, Includes: Factory Installed Rainproof Cover, Standards: UL Listed, Main Cutoff Included, 22000 AIR Short Circuit Current Rating, For Residential, Commercial and Industrial Power Distribution
   
 
1