Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES
Choose a sub category:
BREAKER BOXES MOBILE HOME LOAD CENTERS SPA PANEL BOXES
GENERATOR PANEL BOXES SAFETY SWITCHES DISCONNECT BOXES
METER BASES PANEL BOX ACCESSORIES
Sort By:
1 2 3 4
Plastic (snap-in) for type BR 1" space. May also be used with 400 amp and 600 amp load centers. Covers circuit breaker knock outs that have been removed in error.  Two 1" and two 1/2" plates. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. HOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified. Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. HOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified. Made for QO load centers. Field installed for number 12 - 2 Al or number 14 - 4 Cu wire. QO accessories can only be used with QO load centers.
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 - 1/0 copper and aluminum wire. UL Listed, ANSI Certified. Fits any meter socket application where a closure plate is needed. Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. For meter sockets and combination service entrance devices.
Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws. Steel enclosure. 2 pole, 3 wire, 240 volt AC, rated 10 HP. For central air conditioner. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. 4-3/4" x 7-1/2" x 2". UL1429 enclosure pullout switch, UL Listed. Single phase, 2 pole, 2 wire, 240 volt AC, galvanized steel enclosure with molded case switch. Rated 3 HP at 120 volt, 10 HP at 240 volt. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. 5-3/8" x 8-3/4" x 3-1/8". UL Listed file No.E5239.
Single phase, 2 pole, 2 wire, 240 volt, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32" x 7-5/16" x 2-7/32". UL Listed. Sub feed lug kit. 125 amp. 2 pole. Lugs to sub feed to another panel. Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed.
Main lug indoor load center, 70 amp, 2 spaces/4-circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure, rated as a class 1170. For overhead or underground feed, 1-1/4" maximum knockouts in the top and bottom end walls. ANSI Certified and UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion resistant GE Noryl thermoplastic resin. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. 5-3/4" x 8" x 3-1/8". UL1429 enclosed pullout switch, UL Listed. Steel enclosure. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2" x 9" x 3-1/4". UL869 service equipment, UL Listed.
Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved. Single phase, 1 pole, 2 wire, solid neutral, 120/240 volt AC. Rated 2 HP at 120 volt AC, with metallic enclosure. Typical loads include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. UL Listed, meets NEMA standard KS1. 5.00" x 7.63" x 4.00". Two pole - 200 amp - pair.
For use with 75 degree Celsius wire. 2 pole, 2 wire, 240 volt AC, rated 10 HP, steel enclosure with molded case. With reliable, quick-make, quick-break operating mechanism. Suitable for use on systems with up to 10,000 RMS symmetrical amp available fault current at 240 volt AC maximum when protected by a fuse or circuit breaker rated 60 amp or less. Does not contain overcurrent protection. Ground bar bonded to back. 4-5/8" x 6-1/2" x 3-7/8". UL Listed. Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed. Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved.
Single phase, 2 pole, 2 wire, 240 volt AC. Rated 3 HP at 120 volt, 10 HP at 240 volt. For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8-5/8" x 3-1/2". UL Listed file No. E5239. Single phase, 2 pole, 3 wire, solid neutral, 120/240 volt AC. Rated 3 HP at 240 volt AC, with metallic enclosure. Typical uses include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. 5.00" x 7.63" x 4.00". UL Listed, meets NEMA standard KS1. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt. Ground bar No. GBK5 or No. GBK520 sold separately. Solid copper bus bar and branch fingers. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box - 4-1/2" 9-1/2" x 3-1/8". UL Listed file E8741.
Thermoplastic enclosure. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion resistant GE Noryl resin. Suitable for use as service entrance equipment. Removable closing cap not included. Bonded neutral. 14 - 3 AWG lug wire range. 5-3/4" x 8" x 3-1/8". UL 869 Service Equipment, UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim is installed for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 5-1/8" x 9-7/8" x 2-5/8". For residential or light commercial applications where duty is not severe. 2 pole, 3 wire, plated copper solid neutral and phase conductor parts. Uses plug fuses, 240 volt AC. Rated 1-1/2 HP NEC standard and 3 HP time delay at 240 volt AC, single phase. Typical loads include workshops, pumps, furnaces, water heaters and washers/dryers. Lightweight, corrosion resistant GE Valox thermoplastic enclosure with black matte finish. Front slides vertically to turn on and off. Use only 14-10 AWG copper wire. 4-3/8" x 7-5/8" x 2-1/2". UL Listed (Enclosed Switches No.98); meets or exceeds NEMA standard No.KS1-1990 for type GD enclosed switches. Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed.
Main lug indoor load center, 100 amp,  6 space/12 circuit. NEMA type 1 enclosure with a surface mount cover. 1-1/2" knockouts on the top and bottom of the case. Overhead and underground service feeds. Single phase, 3 wire, solid neutral. UL Listed. Main lug indoor load center, 100 amp, 6 space/12 circuit. 1-1/2" knockouts in the top and bottom end walls to allow for use with either overhead or underground fed electrical wiring. 22,000 short circuit current rating (SCCR) and can be fitted with a secondary surge arrestor (not included) for added protection. Single phase, 3 wire, solid neutral. UL Listed. Single phase - 3 wire; 120/240 volt;  8 circuits maximum with 4 - 1" spaces. 14" length x 8-1/2" width x 3-1/4" depth. 10,000 AIC. UL listed.
Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 6-5/8" x 12-5/8" x 3-1/2". UL Listed, complies fully with NEC and UL requirements for Class CTL. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Steel enclosure. 2 pole, 3 wire, general duty safety switch, plug fuse type, (Type S, T, OR W) fusible with neutral NEMA 1. 120/240 volt rating. 1/2 HP at 120 volt, 1-1/2 HP at 240 volt. Does not have an interlock to prevent opening when switch is in the on position. UL Listed.
Single phase, 2 pole, 2 wire, 240 volt AC, non-metallic enclosure. Rated 1-1/2 HP at 120 volt, 3 HP at 240 volt with time delay fuses (uses class H cartridge fuses, not included). For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. 10,000 amp RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8.63" x 3.5". UL Listed file No. E5239. Indoor flush or surface mount with door. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (6)  1" circuits or (12)  1/2"  circuits. 12-5/8" x 12-3/8" x 3-3/8". UL Listed. Main lug indoor load center, 100 amp, 6 space/12 circuit, intended for use in fixed applications. NEMA type 1 enclosure and a copper bus bar for conductivity. Single-phase, rated for up to 240 volts and has a 10,000 maximum SCCR. UL Listed.
Main lug indoor load center, 100 amp, 6 spaces/12 circuits. 1-1/2" maximum knockouts in the top and bottom end walls for overhead or underground feed. NEMA type 1 for indoor use. Steel enclosure. Single phase, solid neutral. UL Listed. Main lug outdoor load center, 70 amp, 2 space and 4 circuit. NEMA type-3R enclosure with a rainproof cover for outdoor use. Class 1170 unit is intended for use in fixed applications and can accommodate overhead or underground feed. Maximum SCCR of 10,000. ANSI Certified and UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 14 - number 1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Single phase, 2 pole, 3 wire, 2 blades and fuseholders, factory installed solid neutral, 120/240 volt AC. With metallic enclosure for indoor use. Designed to open or close an electrical circuit in general duty applications. Rated 1-1/2 HP. For residential or commercial applications. For PK3GTA-1 field installable service ground bar kit. ANSI Certified and UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Style 5R box. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE 1/2" THQP. (2) 1" or (4) 1/2"  spaces; 22,000 AIC. 7-1/4" x 10" x 3-31/4". Single phase, 2 pole, 3 wire (2 blades, fuseholders and 1 neutral), 120/240 volt AC. Rated 3 HP at 240 volt AC, with metallic enclosure. 10,000 AIC (short circuit rating) with class H cartridge fuses. NEMA type 1 enclosure. Terminal lug data: (1) #12 - 6 Al or #14 - 6 Cu. wire. Service ground bar kit PKGTA1 sold separately. Padlock attachment for lock off. UL Listed, meets NEMA standard KS1. Air conditioning disconnect, molded case switch looks like a circuit breaker but operates like an ordinary household light switch. 60 amp, 2-pole, 240 volt AC. Metallic, galvanized steel enclosure, NEMA 3R, rainproof. Packaged for retail sale. Wire size range Cu or Al at 60 or 70 degrees C: #14-3. UL Listed, CSA Approved.
Designed for residential or light commercial application where duty is not severe. Meets or exceeds NEMA Enclosed Switch Standard KS1-1983 for type GD, CSA certified; 60 degrees C/75 degrees C conductor rating. Two pole, 120/240 volt AC; 250 volt DC. Removable closing cap. Accepts Class H fuses (not included). Feature quick-make, quick-break mechanisms. 6-1/2" x 10-5/8" x 3-5/16". Suitable for use as service entrance equipment when installed in accordance with National Electrical Code. UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 6R box 6-7/8" x 12" x 4-1/2". UL Listed file E8741. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 6 (1") spaces, 12 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741.
Single phase - 3 wire; 120/240 volt;  4 circuits maximum;  2 - 1" spaces ; 10,000 AIC. 9-1/4" x 6-5/8" x 3-3/8". UL Listed. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100-percent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (2) 1" or (4 )1/2" spaces; 22,000 AIC. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4". Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 11-9/16" x 11-3/8" x 3-3/8". UL Listed.
   
 
1 2 3 4