Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES > BREAKER BOXES
Sort By:
1 2
Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4-circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure, rated as a class 1170. For overhead or underground feed, 1-1/4" maximum knockouts in the top and bottom end walls. ANSI Certified and UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed.
Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Two pole - 200 amp - pair.
Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt. Ground bar No. GBK5 or No. GBK520 sold separately. Solid copper bus bar and branch fingers. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box - 4-1/2" 9-1/2" x 3-1/8". UL Listed file E8741. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim is installed for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 5-1/8" x 9-7/8" x 2-5/8". Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed.
Main lug indoor load center, 100 amp,  6 space/12 circuit. NEMA type 1 enclosure with a surface mount cover. 1-1/2" knockouts on the top and bottom of the case. Overhead and underground service feeds. Single phase, 3 wire, solid neutral. UL Listed. Main lug indoor load center, 100 amp, 6 space/12 circuit. 1-1/2" knockouts in the top and bottom end walls to allow for use with either overhead or underground fed electrical wiring. 22,000 short circuit current rating (SCCR) and can be fitted with a secondary surge arrestor (not included) for added protection. Single phase, 3 wire, solid neutral. UL Listed. Single phase - 3 wire; 120/240 volt;  8 circuits maximum with 4 - 1" spaces. 14" length x 8-1/2" width x 3-1/4" depth. 10,000 AIC. UL listed.
Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 6-5/8" x 12-5/8" x 3-1/2". UL Listed, complies fully with NEC and UL requirements for Class CTL. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Indoor flush or surface mount with door. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (6)  1" circuits or (12)  1/2"  circuits. 12-5/8" x 12-3/8" x 3-3/8". UL Listed.
Main lug indoor load center, 100 amp, 6 space/12 circuit, intended for use in fixed applications. NEMA type 1 enclosure and a copper bus bar for conductivity. Single-phase, rated for up to 240 volts and has a 10,000 maximum SCCR. UL Listed. Main lug indoor load center, 100 amp, 6 spaces/12 circuits. 1-1/2" maximum knockouts in the top and bottom end walls for overhead or underground feed. NEMA type 1 for indoor use. Steel enclosure. Single phase, solid neutral. UL Listed. Main lug outdoor load center, 70 amp, 2 space and 4 circuit. NEMA type-3R enclosure with a rainproof cover for outdoor use. Class 1170 unit is intended for use in fixed applications and can accommodate overhead or underground feed. Maximum SCCR of 10,000. ANSI Certified and UL Listed.
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 14 - number 1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Style 5R box. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE 1/2" THQP. (2) 1" or (4) 1/2"  spaces; 22,000 AIC. 7-1/4" x 10" x 3-31/4". Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 6R box 6-7/8" x 12" x 4-1/2". UL Listed file E8741. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 6 (1") spaces, 12 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741.
Single phase - 3 wire; 120/240 volt;  4 circuits maximum;  2 - 1" spaces ; 10,000 AIC. 9-1/4" x 6-5/8" x 3-3/8". UL Listed. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100-percent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (2) 1" or (4 )1/2" spaces; 22,000 AIC. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4". Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 11-9/16" x 11-3/8" x 3-3/8". UL Listed.
Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (8) 1" circuits or (16) 1/2" circuits. 12-5/8" x 12-3/8" 3-3/8". UL Listed. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 4 (1") spaces, 8 poles, 120/240  volt AC. With closure plates, hubs, and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Outdoor main lug load center, 100 amp, 6 space and 12 circuits. Can be wired for underground or overhead feeds with a 2-1/2" hub on the top and a 1-1/2" knockout on the bottom. NEMA type 3R enclosure resists rain for durable performance. ANSI Certified and UL Listed.
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt. Furnished with door. Ground bar No.GBK10 sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting or appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. (4) 1" or (8)  1/2"  spaces; 10kAIC. Single-phase, Three-wire, 120/240 volt AC. 7-1/2" x 9-7/32" x 3-5/16". One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. (4) 1" or (8) 1/2"  spaces. Single-phase, three-wire, 120/240 Volt AC. 7-1/4" x 10" x 3-3/4".
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS style hubs sold separately, uses ECHA075 (694.3559) Hub. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Will not accommodate 2-pole GFCI or circuit breaker with shunt trip. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 5" x 8" x 4-1/4". Convertible to main breaker using double pole breaker. 2 full spaces. 4 space, 8 circuit, combination mount. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces/8 circuits 1-pole, 2 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. With closure plates, HS-hubs sold separately. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and UL Listed, complies fully with NEC and UL requirements for Class CTL. 6" x 12-1/4" x 4-1/4".
Single phase type 1 with 8-1" spaces, 16 circuits. Use neutral lug kit DLK1 or DLK2 as required. Indoor closure with door. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt AC. With closure plates, hubs and ground bar No.GBK5 or No.GBK520 sold separately. Copper bus bar. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coated. Style 5R box 4-1/2" x 9-1/2" x 3-1/8". UL Listed file E8741. Single-phase, Three-wire, 120/240 volt AC. Convertible. Full-length neutrals are easier to wire, reducing installation time and cost. Removable closing cap. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"  THQPs. UL listed. (12) 1 pole 1/2" spaces. 65,000 AIC. 11-1/4" x 11-1/8" x 3-1/4".
Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces and 16 circuits maximum 1-pole, 4 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 amp maximum) is back-fed in branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 12-3/8" x 14-3/4" x 3-7/8". UL Listed, complies fully with NEC and UL requirements for Class CTL. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. 14 spaces, 24 circuits. 14-1/8" x 16-1/8" x 3-3/8". UL Listed. Main lug indoor load center, 125 amp 8 space/16 circuit. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL Listed.
Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Intended for overhead or underground feed. 1-1/4" maximum knockouts in the top and bottom end walls. NEMA 3R enclosure for outdoor use with a factory included cover. Copper bus for conductivity. UL Listed. Main lug indoor load center, 100 amp, 8 space/16 circuit. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. The center is rated for a maximum load of 240 volts and has a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed. Main lug indoor load center, 100 amp, 8 spaces/16 circuits. 1-1/2" maximum knockouts in the top and bottom end walls to accommodate overhead or underground feed. Maximum load of 240 volts and a 10,000 SCCR. NEMA type 1. Copper bus for conductivity. Single phase, 3 wire, solid neutral. UL Listed.
Single phase, 3 wire, Rated 100,000A IR. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when not more than six main disconnecting means are provided. 12 spaces, 24 circuits maximum. 18" height x 14-1/4" wide by 3-7/8" deep. Steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces, 24 poles, 120/240 volt. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as a lighting and appliance panelboard. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 - 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. B1 box - 14-5/16" x 16-3/4" x 3-7/8". UL Listed file E52977. Outdoor main lug load center, 100 amp, 6 space 12 circuit. NEMA type 3R enclosure with a rainproof cover. Copper bus bar, accommodates standard QO or QO tandem circuit breakers. ANSI Certified and UL Listed.
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 8 (1") spaces, 16 poles, 120/240 volt AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Style 7R box 11" x 13" x 3-9/16". UL Listed file E8741. Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 8 spaces/16 circuits 1-pole, 4 QP breakers 2-pole, 120/240 volt AC. 10,000 AIR. HS-hubs sold separately. One piece copper bus bar, 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (125 amp maximum) is back-fed in a branch position, and used with main breaker retainer clip No. MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 12-1/8" x 14-3/4" x 4-1/4". Main lug indoor load center, 125 amp 8 space/16 circuit. Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure, combination flush/surface indoor cover. Overhead or underground feed options. Plated aluminum bus bar. UL Listed.
Single phase, 3 wire, insulated/bondable split neutral, 16 (1") spaces, 24 poles, 120/240 volt. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 - 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. B2 box - 14-5/16" x 18-3/4" x 3-7/8". UL Listed file E52977. Main lug outdoor load center, 125 amp 8 space/16 circuit. Convertible to a main breaker. Single-phase load center. Overhead or underground feed options. Plated aluminum bus bar. UL Listed. Galvanized steel enclosure.  Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 volt.  Main breaker type BR at 10,000 AIC. Tin-plated aluminum bus bar. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. 14-5/16" x 16-3/4" x 3-7/8". UL Listed file E8741.
100A MAIN LOADCENTR
Our Price: $54.56
Convertible to a main breaker with a QOM1 main breaker. Single-phase load center, NEMA type 1 enclosure,  combination flush/surface indoor cover. Overhead or underground feed options. Single phase, 3 wire, 22K A/C main breaker factory installed. Aluminum bus bar, tin plated. ANSI 61 gray powder coated. Suitable for use as service equipment when main breaker is installed or when not more than six main disconnecting means are provided. Convertible from main breaker to main lug. NEMA Type 1. 14.25" width x 3.88" depth. Built with a plated, aluminum bus bar. UL Listed.
   
 
1 2