Green round washer head screw for switch and outlet boxes. For aluminum or copper grounding wire zinc plated. Indoor or outdoor applications. Use to secure the grounding wire to a 1/2" through 1" pipe. UL Listed. Wire size fits #10 - #2 AWG.
Connects grounding wire to the grounding rod. UL and CSA Listed for 1/2" and 5/8" ground rods and number 4 rebar and accept a conductor range from number 10 solid to number 2 stranded. Bolted water pipe clamps made of zinc die-cast. Wire range 8 sol. - 2 str. UL Listed. Connects grounding wire to the grounding rod. Connects grounding wire to the grounding rod.
AWG solid number 12 wire. 8" long with captured screw, other end bare fork terminal. Helps to make a superior connection of ground wire to ground rod. Heavy duty construction for long usage. Indoor or outdoor applications. Use to secure the grounding wire to a 1/2" through 1" pipe. UL Listed. Wire size fits #10 - #2 AWG.
Bolted water pipe grounding clamp. UL listed. Made of corrosion-resistant copper alloy. Connects grounding wire to the grounding rod. Connects grounding wire to the grounding rod.
Bolted water pipe clamps made from high-strength corrosion-resistant copper alloy. Connects grounding wire to the grounding rod. Range 10 solid - 2 stranded. UL Listed. Indoor or outdoor applications. Use to secure the grounding wire to a 1/2" through 1" pipe. UL Listed. Wire size fits #10 - #2 AWG. Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed.
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Bronze alloy grounding clamp with bronze screws. Used for rebar, ground rods, water pipes and direct-burial water pipe. Lay-in feature cuts installation time. Approved for direct burial in earth and concrete. Pipe range from 1/2" (12.7 mm) to 1" (25.4 mm). Rebar range from #4 (10 mm) to #8 (25 mm). Ground rod range from 1/2" (12.7 mm) to 1" (25.4 mm). Conductor range from #10 (5.5 mm sq) to #2 (25 mm sq). UL listed. Bronze alloy grounding clamp with bronze screws. Used for rebar, ground rods, water pipes and direct-burial water pipe. Lay-in feature cuts installation time. Approved for direct burial in earth and concrete. Pipe range from 1/2" (12.7 mm) to 1" (25.4 mm). Rebar range from #4 (10 mm) to #8 (25 mm). Ground rod range from 1/2" (12.7 mm) to 1" (25.4 mm). Conductor range from #10 (5.5 mm sq) to #2 (25 mm sq). UL listed.
Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Wire size fits #10 - #2 AWG. Use to secure the grounding wire to a 1-1/4" - 2" or 2-1/2" - 4" pipe. Bronze. UL Listed.
For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1.
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Indoor or outdoor applications. Use to ground a wiring device to a steel outlet box. Green color. Bolted water pipe clamps made from high-strength corrosion-resistant copper alloy. Connects grounding wire to the grounding rod. Range 10 solid - 2 stranded. UL Listed.
Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1.
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Zinc-coated exteriors are hot-dip galvanized for solid protection against corrosion in accordance with ASTM specification A153-78. Surfaces are rigidly inspected to eliminate seams, slivers and other defects. Meet EEI-NEMA TDJ-30 and are REA listed. 15 year service life in most soils. Galvanized plated steel. Machined from 100 percent high conductivity copper. Irreversible connection, excellent mechanical strength. Fast and simple installation, only requires a hammer. Provides a visual indication of completed connection. 100 percent of the conductor and ground rod circumference surface areas are used in the connection. Allows for "T" or pass-through connections. UL Listed (2, 4, 6 solid to 5/8" copper or galvanized rod).
AWG number 12 solid wire. 6-1/2" long with captured screw, other end stripped. Copperbonded, resists corrosion better than galvanized rods, allowing for a 30-year service life in most soils. Uniform plating thickness, average tensile strength of 80,000 psi and straightness tolerance of .010" per linear foot. Exceeds the requirements of ANSI/UL 467-1984, CSA, and ANSI/NEMA GR-1. The driving head fits over the ground rod to protect the rod end from "mushrooming" as the ground rod is driven into earth.
Intersystem bonding termination for residential and small commercial facilities. Meets the requirements of 2008 NEC Article 250.94.  Accommodates (5) 14 - 2 AWG bonding conductors and (1) 6 - 2 AWG grounding electrode conductor. Integral mounting base for easy installation. The polymeric base and housing is impact-resistant, UV-stabilized and meets UL requirements for weatherability performance. Includes corrosion-resistant, stainless steel mounting hardware. Connects to grounding electrode conductor - does not rely on meter base enclosure bonding connection. 1.41" depth x 2.01" width x 4.5" length. cULus Listed. For grounding switch and outlet boxes using non-metallic sheathed cables from No. 14 to No. 10.
   
 