Home > HEATING & COOLING > FIREPLACE & ACCESSORIES > STOVE PIPE & ACCESSORIES > CHIMNEY PIPE ACCESSORIES
Sort By:
1 2
Use with round flashing to insure water-tight installation. Use with round flashing to insure water-tight installation. Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning.
Designed to fit on the round chimney pipe just above the roof flashing. The upper edge of the collar should be waterproofed with plastic sealer to prevent any water from leaking between the collar and chimney pipe. Part is tightened with screws or tabs after proper positioning. Round collar fits lower end of suspended insulated chimney pipe to provide finished appearance. Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to insulated Tee.
Included in ceiling support assembly, roof support assembly and tee assembly. Included in ceiling support assembly, roof support assembly and tee assembly. Round collar fits lower end of suspended insulated chimney pipe to provide finished appearance. Used to attach T-DSA Smoke Pipe Adapter to lower end of chimney or to insulated Tee.
Prevents or delays the rapid spread of fire (regardless of the cause) in a home or building. The sheet metal firestop prevents the chimney passageway from becoming an easy pathway for fire to spread from one floor to another. Diamond shaped 1/2" x 1" mesh, 18-8 stainless steel. Fits same size round chimney top. Keeps foreign objects out of chimney. Used along the wall to provide for 2" clearance and assure stability. Useful for suspending offsets. Required at 8' or closer intervals to stabilize the chimney, wherever it is supported along a vertical wall.
Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall while maintaining proper 2" clearance to wall, and bracing chimney if height is 5' (or higher) above the roof. Inner and outer pipe. The outer pipe, made of galvanized steel, provides cooling air necessary to maintain safe chimney temperatures, while the inner pipe, made of stainless steel, emits gases out of the fireplace. Snap- lock design. 12" standard pipe (12" inner diameter, 15 3/8" outer diameter) UL127 Listed 1700 Degree Pipe. Provides a finished appearance where the chimney passes through a sloped ceiling. Matte black finish. Adjusts to multiple roof pitches. Covers 4" space around chimney pipe (or 2" further than the required clearance).
Used along the wall to provide for 2" clearance and assure stability. Useful for suspending offsets. Required at 8' or closer intervals to stabilize the chimney, wherever it is supported along a vertical wall. Bracket for supporting the chimney pipe offsets, securing outdoor chimney to exterior wall while maintaining proper 2" clearance to wall, and bracing chimney if height is 5' (or higher) above the roof.
Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage. Provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. Stainless steel and heavy gauge steel construction for long life. Retains chimney with a twist-lock connection.
Installs quickly and eliminates need for using individual firestops. Round shielding acts as a radiation shield and provides the required 2" air space clearance to combustibles. The 2 sections telescope to accommodate 6" to 11" wall thickness. The hole opening in the wall for No. 206463 is 8.25"; for No. 207463 - 9.25"; and No. 208463 - 10.25". Allows for two different methods of chimney resupport. First method is used at the immediate section of chimney above the upper elbow of an offset. Second method is used primarily when the immediate sections of the upper offset do not pass through a joist area and resupport is necessary. Support band is clamped around the chimney immediately below a locking band.  Straps are nailed to suitable framing at two inch clearance. Fits all roof pitches and requires only simple framing. Brackets and mounting hardware only.
Installs quickly and eliminates need for using individual firestops. Round shielding acts as a radiation shield and provides the required 2" air space clearance to combustibles. The 2 sections telescope to accommodate 6" to 11" wall thickness. The hole opening in the wall for No. 206463 is 8.25"; for No. 207463 - 9.25"; and No. 208463 - 10.25". For use in new installations, this part can be installed by twist-locking the coupler on the DSAC into the first section of Sure-Temp-Type HT chimney pipe. Used to seal the opening where the chimney penetrates the roof and to direct rain and snow down from the roof and away from the chimney system. A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings.
Standard flashings fit various pitch roofs. Its double seamed construction protects from water leakage. Designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft. For use in new installations, this part can be installed by twist-locking the coupler on the DSAC into the first section of Sure-Temp-Type HT chimney pipe.
Provides a secure attachment for the chimney to smoke chamber outlet on masonry fireplaces, reducing footing loads and speeding construction. Stainless steel and heavy gauge steel construction for long life. Retains chimney with a twist-lock connection. Tested for use fully enclosed and has been designed in 5, 6, 7 and 8 inch sizes to carry up to 60' of height. Intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection. Also useful where the pipe connection passes through a combustible interior or exterior wall. Braces may only be fastened to the wall above or below the plate for chimneys which penetrate through the wall. Used to seal the opening where the chimney penetrates the roof and to direct rain and snow down from the roof and away from the chimney system. A series of adjustable flashings are available depending on your roof pitch. A flat and low pitch flashing is used to seal flat and low pitch roof (up to 2/12 pitch) openings.
Used with tee branch and chimney section to provide proper clearance to combustible materials. Matte black painted surface for interior wall eliminates need for trim plate. With proper framing, all ceiling supports provide at least 2" minimum clearance to combustibles at the support level and can carry up to 50' of vertical chimney height. Used wherever a ceiling support, finish support, firestop or joist shield is installed below an open attic. Required to guard against the hazard of blown-in or blanket insulation filling any framed opening or contacting the chimney and possible storage of combustibles against the chimney.
Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load, and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4' to 6'. Use when chimney is installed in standard ceiling. 6" and 8" sizes fit between regular 16" O.C. ceiling joists. For exposed beam ceiling installations, use Roof Support. Cartoned to contain stainless steel matte black single wall adaptor. Used whenever there is a need to stabilize the chimney above the roof level. The purpose of the bracing is to hold the chimney against wind load, and to prevent damage from static and sliding snow. It should be used, at a midpoint on the chimney. Bracket adjusts from 4' to 6'.
Used with tee branch and chimney section to provide proper clearance to combustible materials. Matte black painted surface for interior wall eliminates need for trim plate. Round termination features its own built-in spark arrestor. Protects against rain, debris and birds entering chimney. With proper framing, ceiling supports provide at least 2" minimum clearance to combustibles at the support level and can carry up to 50' of vertical chimney height.
With proper framing, all ceiling supports provide at least 2" minimum clearance to combustibles at the support level and can carry up to 50' of vertical chimney height. Use when chimney is installed in standard ceiling. 6" and 8" sizes fit between regular 16" O.C. ceiling joists. For exposed beam ceiling installations, use Roof Support. Cartoned to contain stainless steel matte black single wall adaptor. Tested for use fully enclosed and has been designed in 5, 6, 7 and 8 inch sizes to carry up to 60' of height. Intended for use with the Insulated Tee as an interior or exterior support where the chimney has a lateral connection. Also useful where the pipe connection passes through a combustible interior or exterior wall. Braces may only be fastened to the wall above or below the plate for chimneys which penetrate through the wall.
With clean out, heavy gauge attaches to wall support, chimney tee and chimney. Includes removable plate for clean-out. For exposed-beam ceiling installations. Available in flat to 12/12 pitch (Standard) and for steeper pitches of 13/12 to 18/12 pitch and 19/12 to 24/12 pitch. Use ceiling support when chimney is to be installed in standard ceiling. Contains stainless steel matte black single wall adaptor.
Contains one 18" length of pipe, roof brackets and necessary hardware. Note: Not for use with coal burning stoves. Designed with a dome to exclude rain and leaves and a lower skirt to deflect wind for proper chimney draft. Includes the basic components for a standard installation; CT - Round Top,  AF-6 - Adjustable Flashing, and SC - Storm Collar. 2/12 - 6-12 pitch.
For exposed-beam ceiling installations. Available in flat to 12/12 pitch (Standard) and for steeper pitches of 13/12 to 18/12 pitch and 19/12 to 24/12 pitch. Use ceiling support when chimney is to be installed in standard ceiling. Contains stainless steel matte black single wall adaptor. For 12" standard and high temperature pipe. Round termination features its own built-in spark arrestor. Protects against rain, debris and birds entering chimney.
Built to last with a system combining corrosion resistant stainless steel and sturdy galvanized steel.   It features a space-age ceramic fiber refractory blanket to withstand intermittent temperatures up to 2100 degrees F, is  noncombustible, thin and lightweight. It features the same small outer dimensions and is compatible with the AmeriVent Model FB. It is light enough to be easily installed by one man. Kit contains stainless steel cap, standard flashing, storm collar, ceiling support and single wall adaptor. Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the Tee snout, using a Locking Band, to pass safely through combustible walls. An Insulated Tee Cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated Tee is 50'. Can be used for fixed offsets of 15 degrees slope or in pairs for offsets adjustable from zero degrees to 30 degrees slope. Greater angles are prohibited by UL standard 103 and by the terms of the product listing. Required: Locking bands (2 packaged with each elbow kit) allow 360 degree rotation and lock the components together in place at the exact offset required. Insulated elbows can be used at the same two-inch air space clearance as chimney sections. Includes 2 elbows, 2 locking bands, an interior resupport, and couplers.
Roof flashing with 24" base, firestop spacer, round termination cap, storm collar and flue extension. Fits standard 8" inner diameter, 12-3/8" outer diameter, 1700 degree pipe. For installation of a chimney in a cathedral or pitched ceiling such as standard A-Frame construction. Provides all necessary parts for a complete installation with the exception of the required insulated pipe lengths and an adjustable flashing. Selection of the adjustable flashing is determined by the pitch of your roof and ceiling. Contents: Round top, Smoke pipe adapter, Storm collar, Finishing collar, Adjustable pitch ceiling plate and Roof support package. Used to start chimneys indoors or outdoors using a wall support assembly or a masonry pier. A length of insulated chimney pipe is attached to the Tee snout, using a Locking Band, to pass safely through combustible walls. An Insulated Tee Cap is included which can be removed from bottom opening for inspection and cleanout. Maximum height of chimney which can be supported by an insulated Tee is 50'.
   
 
1 2