Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - GFCI
Sort By:
1
HomeLine HOM115GFICP GFCI Circuit Breaker HomeLine HOM120GFICP GFCI Circuit Breaker BREAKER GFCI 5MA 1P 10KAIC 15A
GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI.
BREAKER GFCI 5MA 1P 10KAIC 20A BREAKER 15AMP GFCI SELF TEST  BREAKER 20AMP GFCI SELF TEST
Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity.
GFCI INTERUPTER 15AMP 1POLE   GFCI INTERUPTER 20AMP 1POLE   GFCI INTERUPTER 30AMP 1POLE
Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 4.5" height x 1.25" width x 3" depth, .479 lb.
MES MP120GF Type MP-T GFCI Circuit Breaker MES QF120 GFCI Miniature Circuit Breaker Square D QO120GFICP Type QO GFCI Circuit Breaker
Protects against shock hazard where water and electricity are present. 120 / 240 volts. UL listed. 1 pole, 1" wide. For use on circuits where contact with water or another ground is possible while using an electrical device. 120 volt, 1 pole circuit breakers. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre.
Square D QO115GFICP Type QO GFCI Miniature Circuit Breaker Square D QO130GFI Type QO GFCI Circuit Breaker BREAKER CH 15AMP GFCI SELFTEST
Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Intended for protection of entire branch circuits where damp-location shock hazards may exist. The unit features a thermal-magnetic tripping mechanism with a red Visi-Trip indicator to identify a tripped breaker. 120 volt, 10,000 AIR. 1 space per breaker. CSA approved Canadian Square D QO loadcentre. Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity.
BREAKER CH 20AMP GFCI SELFTEST MES QF250 GFCI Miniature Circuit Breaker GFCI INTERUPTER 30AMP 2POLE
Automatically senses hot wire-to-ground faults and shuts off the power. Auto-monitoring function provides periodic automatic testing of GFCI. If the self-test detects that GFCI protection might be compromised it indicates an alert.10 kAIC capacity. Non-interchangeable trip. GFCI breakers are ideally suited for the protection of hot tubs, spas and other large loads requiring GFCI protection. 120/240 volt. Tin plated copper stab to create a reliable, permanent and corrosion resistant connection. Ensures its ground circuitry is functioning properly by automatically running diagnostic testing on a periodic basis. Should a problem be detected, the circuit breaker will trip and will need to be replaced. Unit provides protection against overloads, short circuits and ground faults. Class A 5mA ground fault circuit interrupter. Wire range is #14-8 AWG CU/#12-8 AWG AL. UL Listed. 3" height x 2.25" width x 4.5" depth, .858 lb.
HomeLine HOM250GFICP GFCI Standard Circuit Breaker TBR 1GFI ST BKR 20A2P 120/20V TBR 1GFI ST BKR 30A2P 120/20V
GFCI circuit breaker offers protection of entire branch circuits where damp-location shock hazards may exist, as well as Class A overload and short-circuit protection. Class A denotes a GFCI that will trip when a fault current to ground is 5 milliamperes or more. Yellow push to test button. CSA approved. Rated 10,000 AIR and 120/240 VAC. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.
TBR 1GFI ST BKR 50A2P 120/20V TBR 1GFI ST BKR 60A2P 120/20V
GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375. GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2 pole, requires two 1" spaces. 120/240 volt. Meets Federal Spec Classification W-C375.
   
 