Home > ELECTRICAL > ROUGH ELECTRICAL > PANEL BOXES
Choose a sub category:
BREAKER BOXES MOBILE HOME LOAD CENTERS SPA PANEL BOXES
GENERATOR PANEL BOXES SAFETY SWITCHES DISCONNECT BOXES
METER BASES PANEL BOX ACCESSORIES UTILITY POWER OUTLETS
Sort By:
1 2 3 4
Cutler Hammer BRFPP Filler Plate GROUND BAR 7 HOLE CONSUMER PK GE THFILLER Rectangle Filler Plate
Plastic (snap-in) for type BR 1" space. May also be used with 400 amp and 600 amp load centers. For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 - 8 AWG copper or 12 - 8 AWG aluminum terminals and 3 large holes for 14 - 4 AWG copper or 12 - 4 AWG aluminum terminals. UL Listed and ANSI Certified. 6.875" height x 2.875" width x 0.5" depth, .105 lb. Covers circuit breaker knock outs that have been removed in error.  Two 1" and two 1/2" plates.
LUG KIT NO6-2/0 NEUTRAL/GROUND Schneider PK3GTA-1CP Ground Bar Kit Square D QO70AN Auxiliary Neutral Lug Kit
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL Listed. 2.875" height x .75" width x  6.875" depth, .07 lb. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Made for QO load centers. Field installed for number 12 - 2 Al or number 14 - 4 Cu wire. QO accessories can only be used with QO load centers.
Square D QOFPCP Filler Plate Square D PK4GTACP Ground Bar Kits GROUND BAR 24 HOLE PM-GOLD PK
Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL Listed and ANSI Certified. 11" height x 3.5" width x 0.5" depth, .304 lb.
Square D PK7GTACP Ground Bar Kits Square D HOMFPCP Filler Plate Square D HOM100AN Neutral Lug Kit
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified. Breaker box neutral lug is designed for Homeline load centers. It works with number 1 - 1/0 copper and aluminum wire. UL Listed, ANSI Certified.
Square D ACPCP Closing Plate Schneider PK9GTACP Ground Bar Kit Square D PK12GTACP Ground Bar Kits
Used for sealing off a hub opening when a service feed originates underground. The plate is compatible with A-type openings and can be used on outdoor devices that utilize a 4-hole mounting pattern. Use for A-size hub opening for Square D metering equipment. UL and CSA Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
Cutler-Hammer GBK10P Ground Bar Kits Siemens EC2GB152 Ground Bar Kit With Terminal 2/0 Lug Siemens EC38595 Closure Plate
Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1. Fits any meter socket application where a closure plate is needed.
Cutler-Hammer GBK14P Ground Bar Kits Square D PK15GTACP Ground Bar Kits Schneider PK18GTACP Ground Bar Kit
Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed.
Square D PK23GTACP Ground Bar Kits Siemens Energy ECGB10 Ground Bar Kits Siemens EC3GB302 Ground Bar Kit With Terminal 2/0 Lug
Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1. For equipment grounding provision. #14 to 4 AWG, 60/75 degree Celsius, Cu/A1.
GE Electrical TFN60RCP AC Disconnect Switches Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch Cutler Hammer GBK21P Ground Bar Kit
Steel enclosure. 2 pole, 3 wire, 240 volt AC, rated 10 HP. For central air conditioner. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. 4-3/4" x 7-1/2" x 2". UL1429 enclosure pullout switch, UL Listed. Single phase, 2 pole, 2 wire, 240 volt AC, galvanized steel enclosure with molded case switch. Rated 3 HP at 120 volt, 10 HP at 240 volt. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. 5-3/8" x 8-3/4" x 3-1/8". UL Listed file No.E5239. Bar wire holes are suitable for (1) #14-4 or up to (3) #14-10 aluminum or copper wire. Multiple wires in a single hole must be of the same size and material. Distance between mounting holes is 1-3/4". NOTE: Consult local code for correct application of ground bar kit for service entrance equipment. Kit contains one ground bar and two #10-32 x 5/8" self-threading screws. UL Listed.
Siemens Energy WN2060U AC Disconnect Switches Siemens ECLK2125 Sub-Feed Lug Kit Square D S106 Replacement Screw
Single phase, 2 pole, 2 wire, 240 volt, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32" x 7-5/16" x 2-7/32". UL Listed. Sub feed lug kit. 125 amp. 2 pole. Lugs to sub feed to another panel. Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws.
Square D QO2L30SC Load Center Cutler-Hammer DPF221RP AC Disconnect Switches Homeline Square D HOM24L70S Load Center
Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed. Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM24L70F Load Center Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches Eaton BR24L70SP Load Center
Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed. Single phase, 2 pole, 2 wire, 240 volt AC. Rated 3 HP at 120 volt, 10 HP at 240 volt. For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8-5/8" x 3-1/2". UL Listed file No. E5239. Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741.
Eaton BR24L70FP Load Center GE Electrical TPN60R1 AC Disconnect Switches Square D L211N Safety Switches
Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion resistant GE Noryl thermoplastic resin. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. 5-3/4" x 8" x 3-1/8". UL1429 enclosed pullout switch, UL Listed. Single phase, 2 pole, 3 wire, solid neutral, 120/240 volt AC. Rated 3 HP at 240 volt AC, with metallic enclosure. Typical uses include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. 5.00" x 7.63" x 4.00". UL Listed, meets NEMA standard KS1.
GE Electrical TF60RCP AC Disconnect Switches Cutler Hammer BRL200 Main Lug Kit Square D L111N Fusible Light Duty Safety Switch
Steel enclosure. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2" x 9" x 3-1/4". UL869 service equipment, UL Listed. Two pole - 200 amp - pair. Single phase, 1 pole, 2 wire, solid neutral, 120/240 volt AC. Rated 2 HP at 120 volt AC, with metallic enclosure. Typical loads include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. UL Listed, meets NEMA standard KS1. 5.00" x 7.63" x 4.00".
Square D QO200TRCP Molded Non-Fusible Disconnect Switch Eaton CH2L70SP Load Center PowerMark Gold TL412C Standard Load Center
For use with 75 degree Celsius wire. 2 pole, 2 wire, 240 volt AC, rated 10 HP, steel enclosure with molded case. With reliable, quick-make, quick-break operating mechanism. Suitable for use on systems with up to 10,000 RMS symmetrical amp available fault current at 240 volt AC maximum when protected by a fuse or circuit breaker rated 60 amp or less. Does not contain overcurrent protection. Ground bar bonded to back. 4-5/8" x 6-1/2" x 3-7/8". UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt. Ground bar No. GBK5 or No. GBK520 sold separately. Solid copper bus bar and branch fingers. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box - 4-1/2" 9-1/2" x 3-1/8". UL Listed file E8741. Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed.
Cutler-Hammer DPF222RP AC Disconnect Switches Square D QO24L70S Load Center Eaton BR48L125FP Load Center
Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved. Main lug load center, intended for fixed applications. 70 amp, 2 spaces/4 circuits. Surface mount cover with door and a NEMA type 1 enclosure for indoor use. Single phase unit, features a copper bus for conductivity and is rated for up to 10,000 SCCR. ANSI Certified and UL Listed. Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741.
Eaton BR48L125SP Load Center Murray LC004NSU Load Center Homeline Square D HOM612L100S Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 volt. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single phase - 3 wire; 120/240 volt;  8 circuits maximum with 4 - 1" spaces. 14" length x 8-1/2" width x 3-1/4" depth. 10,000 AIC. UL listed. Main lug indoor load center, 100 amp,  6 space/12 circuit. NEMA type 1 enclosure.  Single phase, 3 wire, solid neutral. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers.
Homeline Square D HOM612L100F Load Center PowerMark Gold TLM612FCUD Standard Convertible Load Center Cutler-Hammer DP221NGB Safety Switches
Main lug indoor load center, 100 amp, 6 space/12 circuit. 1-1/2" knockouts in the top and bottom end walls to allow for use with either overhead or underground fed electrical wiring. 22,000 short circuit current rating (SCCR) and can be fitted with a secondary surge arrestor (not included) for added protection. Single phase, 3 wire, solid neutral. UL Listed. Indoor flush or surface mount with door. Box is significantly smaller and lighter while maintaining optimum wire-bending space. Side mounted main  breaker allows top or bottom feed. Sturdy copper bus and galvanized box increase durability and reliability; tinplated for corrosion resistance. Minimum 100 per cent neutral terminations. All neutral holes rated for 14-4 wire. Extruded neutrals are easier to wire, reducing installation time and cost. Combination slotted/Robertson screws speed wiring. Accepts GE Q-Line branch circuit breakers, including GE's exclusive 1/2" THQPs. Interior removes and reinstalls easily. Main breaker not included. (6)  1" circuits or (12)  1/2"  circuits. 12-5/8" x 12-3/8" x 3-3/8". UL Listed. Steel enclosure. 2 pole, 3 wire, general duty safety switch, plug fuse type, (Type S, T, OR W) fusible with neutral NEMA 1. 120/240 volt rating. 1/2 HP at 120 volt, 1-1/2 HP at 240 volt. Does not have an interlock to prevent opening when switch is in the on position. UL Listed.
Eaton BR612L125SP Load Center Cutler-Hammer ACD221RNMP AC Disconnect Switches Eaton BR24L70RP Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single phase, 2 pole, 2 wire, 240 volt AC, non-metallic enclosure. Rated 1-1/2 HP at 120 volt, 3 HP at 240 volt with time delay fuses (uses class H cartridge fuses, not included). For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. 10,000 amp RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8.63" x 3.5". UL Listed file No. E5239. Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Style 5R box.
Eaton BR612L125FDP Load Center Siemens E0204ML1060SU Load Center Siemens E0408ML1125SU Load Center
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 volt. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. Number 14 - number 1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 7 box - 11" x 13" x 3-9/16". UL Listed file E8741. Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits maximum 1-pole, 1 QP breaker maximum 2-pole, 120/240 volt AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim is installed for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. UL Listed, complies fully with NEC and UL requirements for Class CTL. 5-1/8" x 9-7/8" x 2-5/8". Code-gauge steel enclosure. Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits maximum 1-pole, 2 QP breakers maximum 2-pole, 120/240 volt. 10,000 AIR. One piece plated aluminum bus bar. 100 percent circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp maximum) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. 6-5/8" x 12-5/8" x 3-1/2". UL Listed, complies fully with NEC and UL requirements for Class CTL.
   
 